AEC - Your Full Switchboard Checklist




















































































Incoming ACB & Busbar Current Ratings
- 630A / 800A / 1000A / 1250A / 1600A / 2000A / 2500A / 3200A / 3600A / 4000A / 5000A / 6300A
- - - - - - - - - - - - -
Incoming Supplies Incomers & Buscouplers
- Transformer Incomer(s)
- Generators Incomer(s)
- Other Incomer(s)
- Buscoupler(s)
- - - - - - - - - - - - -
- N (Single Incomer - Primary)
- N+1 (Dual Incomer – Primary & Secondary)
- 2N (Primary Incomer – Buscoupler – Primary Incomer)
- 2N+1 (Dual Incomers – Primary & Secondary, Buscoupler, Dual Incomers – Primary & Secondary)
- Etc.
- - - - - - - - - - - - -
- 36KA
- 50KA
- 70KA
- 100KA
- Please note Busbars & Devices, both need to be rated to the associated Fault Rating
- - - - - - - - - - - - -
Switchboard Enclosure Specification
- Enclosure Sheet Metal Thickness
- Fully Welded Enclosure
- Mechanical Strength (Lifting)
- Paint Colour
- Protection against Electric Shock
- - - - - - - - - - - - -
- Standard 50mm
- Size as required, typically in 25mm increases
- - - - - - - - - - - - -
Cable Access – Front or Front & Rear
- Front Access (Cabling Accessible from the Front)
- Front & Rear Access (Cabling Accessible from the Rear)
- - - - - - - - - - - - -
Cable Entry – Top / Bottom / Special
- Top Entry / Bottom Entry
- Top Exit or Bottom Exit / Top & Bottom Exit
- Special, always detail it clearly and precisely
- - - - - - - - - - - - -
- There are more Forms but these are the main two, I wouldn't advise you specify anything less
- Form 3b Type 2 (Typically Panelboards, although Form 4 for me is a must)
- Form 4a Type 2 / Form 4b Type 5 / Form 4b Type 6 / Form 4b Type 7
- - - - - - - - - - - - -
- IP 31 is pretty standard for indoor use but others can be specified
- If its external you will have to consider enclosures (GRP or Containers)
- - - - - - - - - - - - -
- ACB’s
- MCCB’s
- Fuse Switches
- Isolators
- - - - - - - - - - - - -
- Non-Auto
- Thermal Magnetic (Schneider, TMD’s)
- Long & Instantaneous Protection (Micrologic – Schneider, ML 2’s)
- Long, Short & Instantaneous (Micrologic – Schneider, ML 5’s)
- Long, Short, Instantaneous & Earth Fault (Micrologic – Schneider, ML 6’s)
- Long, Short, Instantaneous & Earth Leakage (Micrologic – Schneider, ML 7’s)
- - - - - - - - - - - - -
- ACB – No Choice, all Fronted Push Buttons
- MCCB – Either Toggle or Door Interlocked Rotary Handle (Essential Read Up we Reckon)
- Fuse Switch – Door Interlocked Rotary Handle
- - - - - - - - - - - - -
- Fixed Pattern
- Plugin
- Withdrawable
- - - - - - - - - - - - -
- Percentage Amount Spare Capacity
- Copper Connections Only, Plugin Base or Fully Populated
- - - - - - - - - - - - -
- Mechanical, Castell / Ronis Interlocks
- Mechanical, Chain (Beldon) Interlocks
- - - - - - - - - - - - -
- Electrical, Simple Electrical Control
- Electrical, Break before Make Changeover
- Electrical, Make Before Breaker Changeover (Synchronising)
- Electrical, Load Shedding
- Electrical, PLC – Everything Else
- - - - - - - - - - - - -
- Location
- Specification from Basic / Intermediate / Advanced Metering Solutions
- - - - - - - - - - - - -
Surge Suppression & Power Factor Correction
- Surge Suppresion, Type 1 & Type 2
- Power Factor Correction - Size & with/without reactors (Detuned / Non Detuned)
- - - - - - - - - - - - -
- Inter tripping
- Restricted Earth Fault
- Neutral Earthing Contactors
- Neutral Earth Connection
- Active Harmonic Filtration
- - - - - - - - - - - - -
!Design Verification! - DON'T APPROVE A SWITCHBOARD WITHOUT SEEING THESE
- Short Circuit Certification
- Busbar Certification
- Earth Bar Certification
- Temperature Rise
- Switch Room Operational Temperature 40 Degrees C
- Busbar / ACB / MCCB Certification
- - - - - - - - - - - - -